Spaces:
Sleeping
Sleeping
Alegro EIC Code Mapping
Real ENTSO-E Transmission Asset EIC
Source: ENTSO-E Allocated EIC Codes Registry (allocated-eic-codes.xml)
EIC Code: 22T201903146---W
Long Name: ALEGRO DC
Display Name: L_LIXHE_OBERZ
Type: International transmission asset
Status: Active (A05)
Last Updated: 2021-08-11
JAO Custom Alegro EICs (FBMC Market Coupling)
JAO uses 8 custom Alegro constraint EICs for market coupling optimization. These are NOT transmission asset EICs from ENTSO-E - they are virtual constraints.
| JAO Custom EIC | Constraint Name | Purpose |
|---|---|---|
| ALEGRO_EXTERNAL_BE_IMPORT | External Constraint BE_AL_import | BE import capacity constraint |
| ALEGRO_EXTERNAL_BE_EXPORT | External Constraint BE_AL_export | BE export capacity constraint |
| ALEGRO_EXTERNAL_DE_IMPORT | External Constraint DE_AL_import | DE import capacity constraint |
| ALEGRO_EXTERNAL_DE_EXPORT | External Constraint DE_AL_export | DE export capacity constraint |
| ALEGRO_INTERNAL_BE_IMPORT | BE_AL_import | Internal BE import constraint |
| ALEGRO_INTERNAL_BE_EXPORT | BE_AL_export | Internal BE export constraint |
| ALEGRO_INTERNAL_DE_IMPORT | DE_AL_import | Internal DE import constraint |
| ALEGRO_INTERNAL_DE_EXPORT | DE_AL_export | Internal DE export constraint |
Mapping Strategy
For JAO Features
- Use JAO custom EICs (8 constraints)
- Each generates ~20 features (shadow prices, binding frequency, LTA, etc.)
- Total: ~160 Alegro JAO features
For ENTSO-E Outage Features
- Use real transmission asset EIC:
22T201903146---W - Query BE-DE border outages, filter to this EIC
- Generate 4 outage features:
alegro_outage_binary: Current outage indicator (0/1)alegro_outage_planned_7d: Planned outage next 7 days (forward-looking)alegro_outage_planned_14d: Planned outage next 14 days (forward-looking)alegro_outage_capacity_mw: MW capacity offline
Data Reality (Nov 2025)
- Historical outages (Oct 2023 - Nov 2025): ZERO found in ENTSO-E
- Expected: Alegro achieves 93-98% availability → very few outages
- Production Impact: Outage features will be mostly zeros
- Forward-Looking Value: Planned outages (when they occur) are critical future covariates
Automated Collection
Script: scripts/collect_alegro_outages_automated.py
Method:
- Query BE-DE border transmission outages (documentType A78)
- Parse ZIP/XML response
- Extract
Asset_RegisteredResource.mRIDelements - Filter to Alegro EIC:
22T201903146---W - Extract outage periods with timestamps
- Separate planned (A53) vs forced (A54) outages
- Filter to future outages for forecasting
Status: Production-ready automated collection Result: Zero outages found (realistic for high-availability HVDC)
Next Steps
- Accept that Alegro outage features may be sparse (zeros)
- Keep automated collection in production pipeline
- Generate outage features with zero-filling for periods without outages
- Monitor for future planned outages (forward-looking covariates)
Created: 2025-11-09 Last Updated: 2025-11-09 Automated Collection: ✅ Complete